Dell EMC SCv3000 Series Storage

Our most affordable hybrid array

New entry point to SC Series auto-tiering and enterprise-class storage features

SKU
EMC SCv3000 Storage

Specification 

Expansion Capacity

  • Supported expansion enclosures
    SCv300: 12 x 3.5” drive bays (12Gb SAS)
    SCv320: 30 x 2.5” drive bays (12Gb SAS)
    SCv360: 60 x 3.5” drive bays (12Gb SAS)1

    Maximum drive count
    222 per array (internal plus external expansion), more in federated systems2

    Max raw capacity 
    1PB per array3 (SSD or HDD), more in federated systems

    Max raw capacity (NAS)
    1PB per array3 with optional FS8600 or NX3000 Series Windows NAS appliance 

    Storage media
    SAS and NL-SAS drives; different drive types, transfer rates and rotational speeds can be mixed in the same system.
    SSD: write-intensive and read-intensive drives 
    HDD: 15K, 10K, 7.2K RPM

Data Optimization

  • Auto-tiering method 
    Policy-based migration based on real-time data usage, customizable 512KB-4MB page size.

    Auto-tiering structure
    Up to 3 primary (media-based) tiers total, up to 2 SSD tiers (write- and read-intensive SSDs)

    Tiering customizations
    User-defined profiles, option to “pin” volumes to any tier 

    RAID support
    RAID 0, 1, 5, 6, RAID 10, and RAID 10 DM (Dual Mirror); any combination of RAID levels can exist on a single array 

    RAID tiering
    Auto-provisions and dynamically restripes multiple RAID levels on the same tier; no need to pre-allocate RAID groups 

    Thin provisioning
    Active by default on all volumes, operates at full performance across all features 

    Thin snapshots
    Records changes only, snapshots auto-migrate to lower-cost storage 

    Intelligent compression
    Selectable option per volume 
    Applies to SSDs, HDDs or both in hybrid configurations

    HDD optimization
    FastTrack moves frequently accessed data to outer tracks for quicker response times

Physical

  • SCv3000
    Rack size: 3U
    Height: 13.33 cm (5.25 inches)
    Width: 44.5 cm (17.52 inches)
    Depth: 78.5 cm (30.9 inches)
    Weight at maximum configuration: 24.22 kg (53.4 lb)
    Weight empty: 15.15 kg (33.4 lb)

    SCv3020
    Rack size: 3U
    Height: 13.33 cm (5.25 inches)
    Width: 44.5 cm (17.52 inches)
    Depth: 78.5 cm (30.9 inches)
    Weight at maximum configuration: 24.22 kg (53.4 lb)
    Weight empty: 15.15 kg (33.4 lb)

Chassis Overview

  • Chassis format
    All-in-one (dual controllers, internal drive bays, networking and expansion ports) 

    Rack size
    3U

    Controllers
    2 hot-swappable per chassis (active/active) 

    Processors
    Intel® Xeon® Processor E5-2603v4, 1.7GHz, 6 cores

    Internal storage capacity
    SCv3000:
     16 x 3.5” drive bays
    SCv3020: 30 x 2.5” drive bays

    System memory
    32GB per SCv3xxx array (16GB per controller)

    Operating system
    Storage Center OS (SC OS) 7.2 or greater

Network and Expansion I/O

  • Front-end-network protocols
    FC, iSCSI, SAS (supports simultaneous multiprotocol)

    Max 16Gb FC ports
    8 per array (SFP+)

    Max 10Gb/1Gb iSCSI ports
    Up to 8 SFP+ or BaseT ports per array

    Max 12Gb SAS ports
    Up to 8 12Gb SAS ports4 

    Management ports
    2 per array (1Gb BASE-T) 

    Back-end expansion protocols
    12Gb SAS 

    Max back-end expansion ports
    4 per array 
    Up to 16 expansion enclosures per array

Functional

  • Array configurations
    All-flash, hybrid or HDD arrays

    Storage format
    Block (SAN) and/or file (NAS) from same pool5

Data Mobility and Migration

  • Replication
    Replicates with other SC Series arrays6
    Synchronous/Asynchronous via FC or iSCSI
    Target/source relationships may be one-to-many or many-to-one
    Supports all SC data services on source and target volumes
    Change replication types and topologies on demand
    Supports cross-platform replication with PS Series/EqualLogic arrays (either direction)

    Volume mobility
    Live Migrate (included in base product) enables host-transparent data movement among arrays; see also Federation section

    Federated multi-array systems 
    Live Migrate (included in base product) enables host-transparent movement of volumes among arrays
    Snapshots maintained/preserved during migration

    Thin Import
    Space-efficient, non-disruptive data migration from PS Series (EqualLogic) arrays

    Thin Clones
    Clone standalone volumes with zero duplication of data
    Clones maintain independent snapshots and replication
    Ideal for VDI, test/dev, other applications that require discrete instances of common data
    More efficient than dedupe for database copies

Data Protection Features

  • Business continuity 
    Live Volume bi-directional auto-failover, auto-repair7
    Continuous operations, disaster recovery, disaster avoidance 
    Includes third-site (tertiary) replication options with Live Volume Managed Replication8
    Zero RTO/RPO with customizable site failover SLAs per volume 
    Does not require identical hardware at each site 
    VMware Metro Stretch Cluster support 
    VMware Site Recovery Manager 

    Thin snapshots 
    Records changes only, snapshots auto-migrate to lower-cost storage

    Replay Manager 
    Application-consistent snapshots in Microsoft or VMware environments

    Data-at-rest encryption
    Self-encrypting drives (SEDs) in SSD or HDD formats 
    Full Disk Encryption (FCE) based on AES-256
    Drives certified to FIPS 140-2 Level 2 
    Key Management Server (KMS) options available for FIPS 140-2 Level 1, 2 and 3

    External key manager support
    Gemalto’s SafeNet KeySecure k460, SafeNet KeySecure k250, SafeNet KeySecure k150v
    Thales EMS 200

Environmental Operating Conditions

  • Operating temperature: 50 - 95°F (10 - 35°C)
    Non-operating temperature: -40 - 149°F (-40 - 65°C)
    Operating humidity ranges (non-condensing): 10% to 80% with 29°C (84.2°F) maximum dew point
    Non-operating humidity (non-condensing): 5% to 95% with 33°C (91°F) maximum dew point
    Inlet type: NEMA 5-15/CS22.2, n°42

Power

  • Power/wattage: Dual hot-swappable power supplies. Choice of 1378W or 1485W PSUs (1778W or 1485W maximum power)
    Heat dissipation: 1378W PSU: 703 BTU/hr maximum; 1485W PSU: 5,067 BTU/hr maximum
    Voltage: 1378W PSU: 100-240 VAC; 1485W PSU: 200-240 VAC
    Frequency: 50/60 Hz
    Amperage: 1485/100 – 14A, 1485/240 – 6.2A; 1378/100 – 16A, 1378/240 – 8.25A

Management

  • Management interface
    Dell Storage Manager 
    Multi-array, multi-site, cross-platform management from single interface

    Federation 
    Create large multi-array systems under unified management, with seamless workload migration between arrays via included Live Migrate feature. Add arrays non-disruptively, efficiently utilizing their combined capacity and performance. Volume Advisor monitors federated arrays to suggest optimal data placement and load balancing. Volume movement does not impact snapshots or replication data protection. Federate like or unlike arrays: SC9000, SC8000, SC7020, SC5020, SC4020, SCv3000/3020.9

    Scripting support
    Microsoft PowerShell API
    RESTful API

    Host OS support
    Microsoft® Windows Server®, Oracle® Solaris, HP®-UX, Oracle Linux, IBM® AIX®, Novell® NetWare, SLES, Apple, HPTru64, VMware®, Citrix® XenServer®, RedHat®

    Third-party application integration
    VMware, Microsoft, IBM, OpenStack, Oracle, Symantec, Commvault, Foglight, Docker (see SC Series Management spec sheet for more details)

    Coexistence with PS Series arrays
    Replication in either direction 
    Day-to-day management from a single interface
    Thin import: space-efficient, non-disruptive data migration from PS Series arrays

    Certifications
    VMware vSphere Metro Storage Cluster, VMware SRM, Veritas Storage Foundations Suite, IBM VIOS Recognized, Oracle Validated Infrastructure (OVI); see Dell Storage Support Matrix for additional certifications and details

    Reporting/alerts
    Support assist (phone home), remote diagnostics and performance monitoring, automated alerts, reports and notifications, departmental chargeback

    Workload management
    QoS, VVOLs
More Information
Manufacturer Dell
Call